Pay in installments of $28.58 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Aug 4 - Aug 9
For Your Every Summer RSVP, with Code: SUMMER15
Description
LUCA18FUMain Range TeSys Product name TeSys U Device short name LUCA Product or component type Standard control unit Product specific application Basic protection requirements for motor starters: overload and short circuit Product compatibility LUFN.. LUFC00 Utilisation category AC 41 AC 44 AC 43 Motor power kW 15 kW at 690 V AC 50 60 Hz 9 kW at 500 V AC 50 60 Hz 7. 5 kW at 400 440 V AC 50 60 Hz Thermal protection adjustment range 4. 518 A [Uc] control
Main
| Range | TeSys |
| Product name | TeSys U |
| Device short name | LUCA |
| Product or component type | Standard control unit |
| Product specific application | Basic protection requirements for motor starters: overload and short-circuit |
| Product compatibility | LUFN.. LUFC00 |
| Utilisation category | AC-41 AC-44 AC-43 |
| Motor power kW | 15 kW at 690 V AC 50/60 Hz 9 kW at 500 V AC 50/60 Hz 7.5 kW at 400...440 V AC 50/60 Hz |
| Thermal protection adjustment range | 4.5…18 A |
| [Uc] control circuit voltage | 110...220 V DC 110...240 V AC |
| Thermal overload class | Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2 Class 10 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508 Class 20 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to IEC 60947-6-2 Class 20 - frequency limit: 40…60 Hz - temperature compensation: -25…70 °C conforming to UL 508 |
Complementary
| Main function available | Earth fault protection Manual reset Protection against phase failure and phase imbalance Protection against overload and short-circuit |
| Mounting mode | Plug-in |
| Mounting location | Front side |
| Control circuit voltage limits | 88...242 V for DC circuit 110...220 V in operation 88...264 V for AC circuit 110...240 V in operation |
| Typical current consumption | 25 mA at 110...240 V AC I rms sealed with LUB12 25 mA at 110...240 V AC I rms sealed with LUB32 280 mA at 110...220 V DC I maximum while closing with LUB12 280 mA at 110...220 V DC I maximum while closing with LUB32 280 mA at 110...240 V AC I maximum while closing with LUB12 280 mA at 110...240 V AC I maximum while closing with LUB32 35 mA at 110...220 V DC I rms sealed with LUB12 35 mA at 110...220 V DC I rms sealed with LUB32 |
| Operating time | 35 ms opening with LUB12 for control circuit 35 ms opening with LUB32 for control circuit 50 ms closing with LUB12 for control circuit 50 ms closing with LUB32 for control circuit |
| Load type | 3-phase motor - cooling: self-cooled |
| Tripping threshold | 14.2 x Ir +/- 20 % |
| [Ui] rated insulation voltage | 600 V conforming to UL 508 690 V conforming to IEC 60947-1 600 V conforming to CSA C22.2 No 14 |
| [Uimp] rated impulse withstand voltage | 6 kV IEC 60947-6-2 |
| Safe separation of circuit | 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 |
| Net weight | 0.135 kg |
Environment
| Heat dissipation | 3 W for control circuit with LUB32 |
| Immunity to microbreaks | 3 ms |
| Immunity to voltage dips | 70 % / 500 ms conforming to IEC 61000-4-11 |
| Standards | UL 508 type E, with phase barrier EN 60947-6-2 IEC 60947-6-2 CSA C22.2 No 14 type E |
| Product certifications | ABS BV CSA LROS (Lloyds register of shipping) ASEFA ATEX GOST GL DNV UL CCC |
| IP degree of protection | IP20 front panel and wired terminals conforming to IEC 60947-1 IP20 other faces conforming to IEC 60947-1 IP40 front panel outside connection zone conforming to IEC 60947-1 |
| Protective treatment | TH conforming to IEC 60068 |
| Ambient air temperature for operation | -25…70 °C |
| Ambient air temperature for storage | -40…85 °C |
| Operating altitude | 2000 m |
| Fire resistance | 960 °C parts supporting live components conforming to IEC 60695-2-12 650 °C conforming to IEC 60695-2-12 |
| Shock resistance | 10 gn power poles open conforming to IEC 60068-2-27 15 gn power poles closed conforming to IEC 60068-2-27 |
| Vibration resistance | 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6 4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6 |
| Resistance to electrostatic discharge | 8 kV level 3 in open air conforming to IEC 61000-4-2 8 kV level 4 on contact conforming to IEC 61000-4-2 |
| Non-dissipating shock wave | 1 kV serial mode conforming to IEC 60947-6-2 2 kV common mode conforming to IEC 60947-6-2 |
| Resistance to radiated fields | 10 V/m 3 conforming to IEC 61000-4-3 |
| Resistance to fast transients | 2 kV class 3 serial link conforming to IEC 61000-4-4 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4 |
| Immunity to radioelectric fields | 10 V conforming to IEC 61000-4-6 |
Offer Sustainability
| Sustainable offer status | Green Premium product |
| REACh Regulation | REACh Declaration |
| EU RoHS Directive | Compliant EU RoHS Declaration |
| Mercury free | Yes |
| RoHS exemption information | Yes |
| China RoHS Regulation | China RoHS declaration |
| Environmental Disclosure | Product Environmental Profile |
| Circularity Profile | End of Life Information |
| WEEE | The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins |
Contractual warranty
| Warranty | 18 months |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.0 ★★★★★
Based on 15 reviews
Sort
Product Reviews
★★★★★ 5
Works
Size: For 60 65 70 75 HP
Works great
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on May 21, 2026
★★★★★ 4
Great product
Size: For 85-300 HP
Complete rebuild kit for $38 and great quality and fast delivery
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 30, 2025
★★★★★ 5
If pump doesn't seem to work
Size: For 85-300 HP, Size: For 85-300 HP
Hi....I apologize it took me a while to get back to you with my results. Here is what I discovered about the pump and will also apply to some of the other comments I read in the reviews with people not getting the pump to work:
1.) I removed the pump to check the proper direction of the impeller and it was correct as can be seen in the photo.
2.) I built a pump shaft attachement so that I could operate the pump with a power drill.
3.) I attached the water muff to the unit and tried to pump water.....it wouldn't do so. What I did see however was that even at high hose discharge and small leakage at the muff I could not fill the water cavity in the housing.
4.) I installed a strap around the muff and tightened it very tight and THEN at high hose pressure I was able to get the cavity to fill with water.
5.) At that point I activated the drill and was able to get the pump to actually pump water. I then removed the pump housing and removed the O-Ring that resides on top of the impeller, reassembled and it would not pump water. Since the O-Ring sits higher than the original does I wanted to make sure that it was necessary to have it in the pump.
6.) I reassembled the engine and kept the tight strap on the bottom and finally it pumped water into the engine.
My conclusion that you can reply to other buyers if they have a problem:
Do NOT underestimate 2 things....1.)the lack of ability of the pump to draw water up AND 2.)the fact that if the muff leaks it will NOT fill the cavity when common sense says it should. This was a 120hp Johnson. The engine bottom must be immersed fully or the muff must be very tight on the lower unit for the pump to function.
Please feel free to post this if you wish.
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on August 12, 2024
★★★★★ 5
Exelente
Size: For 85-300 HP
Exelente
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 21, 2026
★★★★★ 5
Good as new
Size: Package Dimensions 6.02 x 4.02 x 2.05 inches
Fitment was great and works as it should. Good quality
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on March 19, 2025
recommand products
Selden 508-479-02 Pole Launch Roller Assembly
180.65
Foam Dressing McKesson 6 X 6 Inch With Border Film Backing Silicone Gel Adhesive Square Sterile #4844
246.00
Womens Technical Shorts 2.0
102.40
Solventum Corporation Foam Dressing 3M™ Tegaderm™ 4 X 4-1/4 Inch Without Border Film Backing Silicone Face Square Sterile #90631
159.00
Solventum Corporation Foam Dressing 3M™ Tegaderm™ High Performance 5-1/2 X 5-1/2 Inch With Border Film Backing Acrylic Adhesive Heel Sterile #90619
13.00